Settings Page
The Settings page provides configuration options organized into five tabs accessible via the left sidebar.
Global Thresholds
Configure sensor thresholds for all devices using visual zone-based sliders. Each sensor type displays three zones:
- SAFE zone — Bright emerald green
- WARNING zone — Vibrant yellow
- CRITICAL zone — Bright red
Drag the threshold handles to adjust the boundaries between zones. The range indicator shows the current threshold values with semi-transparent background. Zone labels display with white text overlays and text shadows for contrast.
Supported sensor types:
- Pressure (PSI), Temperature (°C), Vibration (mm/s), Flow Rate (L/min), RPM, Voltage (V), Current (A), Power (kW), Torque (Nm), Humidity (%), Oil Level (%), Gas Concentration (ppm)
All changes take effect immediately without requiring system restarts.
Device Setup
Manage individual devices with the following options:
- Add New Device — Create new device entries with name, type, location, and deployment photo
- Edit Device — Modify device properties including name, type, GPS coordinates
- Upload Deployment Photo — Click the camera icon to upload custom equipment photos (max 5MB)
- Delete Device — Remove devices from the system (requires confirmation)
User Management
Manage operator accounts and permissions:
- Add User — Create new operator accounts with email, name, and role
- Edit User — Modify user properties including name, email, role, and active status
- Delete User — Remove user accounts (requires confirmation)
- Role Assignment — Assign roles (Operator, Engineer, Administrator) with different permission levels
Scheduled Reports
Configure automated email reports summarizing alarm trends and resolution rates:
- Enable/Disable — Toggle scheduled reports on/off
- Frequency — Select Daily, Weekly, or Monthly delivery
- Email Recipients — Add multiple email addresses (comma-separated)
- Include Resolved Alarms — Toggle whether to include resolved alarms in reports
- Include Charts — Toggle whether to include trend charts and visualizations
- Report Preview — View sample report before enabling
- Test Report — Send test report immediately to verify configuration
Reports include:
- Active alarm summary by severity and device
- Resolution rate trends over time
- Top 10 devices by alarm count
- Average time to resolution by severity
- Escalation rate trends
Storm Control
Configure alarm storm suppression to prevent notification fatigue during cascading failures:
- Time Window — Duration in minutes for grouping related alarms (default: 5 minutes)
- Sensor Count Threshold — Minimum number of sensors triggering to classify as storm (default: 3)
- Grouping Rules — How to group related alarms:
- Show Suppressed Alarms — Toggle whether to display suppressed alarms in the table (with "Suppressed" badge)
When storm suppression is active, the group header displays the suppressed count (e.g., "3 suppressed").